Examine This Report on Slip Resistance Inspection Services
Examine This Report on Slip Resistance Inspection Services
Blog Article
ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it pertains to making sure safety in business, industrial, and domestic areas, slip resistance testing is a crucial element. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help services and homeowner mitigate risks and comply with safety requirements.
With state-of-the-art equipment such as the pendulum slip test device and moisture meter for concrete, we offer precise and independent slip testing services throughout Australia. Our proficiency covers ASTM F2170 compliance, R Score evaluations, P Ranking tiles, and more, guaranteeing your floors meet the highest safety criteria.
Why Slip Resistance Testing is Necessary
Slips and falls are amongst the leading causes of workplace and public injuries. Proper slip testing helps determine dangerous surface areas before mishaps take place. Whether you require damp pendulum test examinations or pendulum test for slip resistance, ATTAR provides exact outcomes to boost security.
Secret Services Offered by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Rating and P Rating tiles evaluations.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing advanced moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Ensures visibility for visually impaired people.
- Complies with Australian accessibility requirements.
4. On-Site & Lab Testing
- Slip test maker for precise on-site examinations.
- Wet pendulum test for damp surface area slip resistance.
Understanding Slip Resistance Ratings: R Rating vs. P Rating
When carrying out slip resistance testing, 2 key classifications are utilized:.
- R Score (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, frequently used in Europe.
- P Rating (Pendulum Test - AS 4586)
Assesses vibrant friction utilizing a pendulum test slip resistance device, commonly adopted in Australia.
ATTAR offers independent slip testing to identify whether your flooring satisfies the required pendulum ranking tiles requirements.
The Value of Concrete Moisture Testing
Excess moisture in concrete slabs can result in flooring failures, mold growth, and adhesive degradation. Our concrete moisture testing services consist of:.
> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to ensure ideal conditions for floor installations.
By spotting moisture issues early, we help prevent expensive repairs and guarantee long-lasting flooring performance.
Luminance Contrast for Accessibility Compliance
Proper luminance contrast is crucial for visually impaired individuals to browse spaces safely. ATTAR evaluates:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.
Our evaluations guarantee compliance with Australian Disability Standards (AS 1428.1).
Why Choose ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where relevant).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Fast & Dependable Reporting.
For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Typical Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping centres, restaurants, and workplaces require safe floor covering to prevent client and employee injuries. Our pendulum slip test guarantees compliance with safety guidelines.
2. Industrial & Warehouse Facilities
High-traffic industrial environments require durable, slip-resistant floor covering. ATTAR's slip testing services help keep work environment safety.
3. Health Care & Aged Care Facilities
Healthcare facilities and nursing homes need to minimize slip dangers. Our luminance contrast and slip resistance testing make sure safe mobility for clients and personnel.
4. Public Infrastructure
Paths, train stations, and government structures require independent slip testing to satisfy accessibility and safety requirements.
How ATTAR Carries Out Slip Resistance Testing
Action 1: Surface Evaluation
We examine flooring products and conditions (dry, wet, or contaminated).
Action 2: Pendulum Slip Test (AS 4663)
Using a slip test machine, we determine the dynamic coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Imitates slippery conditions to assess real-world slip threats.
Step 4: Reporting & Compliance Accreditation
Comprehensive reports with R Ranking or P Rating tiles classifications.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance approach includes a swinging arm with a here rubber slider that mimics a foot's motion. The test procedures:.
- Slip Potential Value (SPV).
- Pendulum score tiles category (P0 to P5).
Higher scores (P4/P5) show better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related flooring failures can be expensive. ATTAR's concrete slab moisture testing consists of:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's trusted service provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and compliant testing services.
Ensure your residential or commercial property satisfies security requirements-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By picking ATTAR, you invest in independent slip testing services, pendulum test slip resistance accuracy, and long-lasting floor security options. Let us assist you develop safer, compliant, and moisture-resistant environments. Report this page